Hitech Strive Towards Excellence in quality of each product that manufacture
Looking for best Laminar Airflow chamber Manufactures in Chennai, India? We are Very reputed manufacturer, exporter and supplier of Laminar air flow chamber.
Available in SS 304, SS 316, GI sheet PU Coated, Ply - Lam Constructions. Horizontal / Vertical Laminar Airflow Benches allows operations in a sterile and particle free conditions. Due to continuous flushing of the working area by unidirectional and HEPA Filtered airflow, the equipment assures a full product protection.
International standard HEPA filters, high efficient & washable primary filters, Digital mono meters / Magnehelic / Minihelic gauges for accurate DP reading, spring suspended DIDW blower assembly for high performance at low sound level, SS working surface with curved front for conveneient working.
Cleanliness Level | CLASS 100 |
Particle Retention | 0.3 & above |
Air Velocity | 90 FPM+ 20 |
Noise Level | 65 decibels 5 |
Working Size | 2x2x2 | 3x2x2 | 4x2x2 | 6x2x2 |
Horizontal | HH0600 | HH090 | HH1200 | HH1800 |
Vertical | HV0600 | HV0900 | HV1200 | HV 1800 |
Custom sizes are also available.
Hitech vertical laminar flow class II type B2 biohazard safety cabinets provide personnel and environmental protection. This series of cabinets are referred to as “total exhaust” cabinets because the 100% contaminated air is exhausted to the atmosphere after HEPA filtrations without re-circulating in the cabinet.
Cleanliness Level | CLASS 5 as per ISO 14644-1 |
Particle Retention | 0.3μ & above |
Class I | Class II - Type A2 |
Class II - B2 | Class III |
Other Models also available
Powder Dispensing booths are used to control the hazardous emissions of powders, dust or vapors during Powder Dispensing, product sampling, or bag dispensing etc., without risk to the operator or environment. The downdraught prevents airborne dusts caused by weighing and dispensing operations rising into the operator’s breathing zone.
The air forced downwards is extracted at low level into the booths filtration system where dust particles contained at each level of filtration prior to being re-circulated back into the booths air stream.
Available in SS 304, SS 316, PU Coated GI
Air balancing | 90% Re circulation and 10% exhaust |
Cleanliness | Class 5 of ISO 14644-1 |
Particle Retention | 0.3μ and above |
Noise level | 65 decibel on “A” scale+5 |
Velocity | 90 feet/Minute +20 |
Differential Pressure | By Magnehelic Gauge 0-25 mm |
illumination | By Florescent Tubes with Diffusers |
Power supply | 230V single phase, 50 Hz |
Air showers are installed to avoid contamination through personnel entry in to a cleanroom. Air showers employ concentrated airflows to lift off contamination such as LINT, DIRT, DUST ETC., While an individual walks through chamber. The high velocity air from jet nozzels ensures efficient scrubbing action necessary to remove particulate matter. Contaminated air then flows through sidewalls of the air shower and flows through prefilters and final HEPA filters
Hitech pass through box is designed to minimize traffic and contamination entry into the clean room. Enable movement of materials to and from cleanroom. Acts as an air lock device to prevent cross contamination between to adjacent environments.
Available in Static & Dynamic versions to suit requirement.
The garment storage cabinets are used inside the controlled environments. These cabinets provide CLASS 100 clean storage space with UV disinfectant and warming by IR lamps. Air balancing : 90% re circulating and 10% exhaust.
THitech Pressure Modules available in SS 304, GI PU Coated provides HEPA filtered airflow to creat positive pressure within smaller enclosures. Ambient air is filtered upto 5 micron level through primary filters and the HEPA filter removes particles of 0.3 micron and larger.
Available in 500 & 1000 CFM capacities in window mounted / Ceiling Mounted self standing models.
Hitech ceiling suspended laminar air flow (CSLAF) are used for operation theatre applications, pharms filing & packing line etc. CSLAF provides ultra clean sterile HEPA filtered class 100 air a isolated area where the highly sensitive process activities are carried-out.
CSLAF available in complete stainless steel construction or GI construction with PU coated.
Equipped with minipleat HEPA filter with dynamically balanced ultra-low noise blowers for optimum airflow.
Available C.R.C.A. sheet construction with epoxy coated finish, GI construction with PU coated finish and Wood melamine construction.
Hitech Fume Exhaust hoods used to drive-out hazardous chemical fumes, odors and gases generated during the laboratory process work. Hitech Fume hoods are available in ducted or ductless types.
Work Surface made of polished granite or glazed ceramic tiles.
Single vertical sliding concealed type glass door balanced by counter weights with SS Rope
Available with wide range of accessories such as sink, water inlet & gas / air / vaccum pet cocks, power points optional FLP fittings under bench cup-board etc.
Customized Hitech Laboratory furnitures made exclusively to suit the plinth of your Lab floor. Wide range of modular configuration to suit the flexbility that your labs demand.
Made of heavy duty C.R.C.A Sheet, galvanized iron sheet with epoxy powder coated finish, with finely polished granite top mounted on anti vibration pads.p>
features include adjustable floor leveling screws, anti-vibration pads between granite top and the main frame, water, SS Sinks with goose neck water inlets & outlets, power sockets and optional lightings, Stainless steel/brass hinges, handles/knobs and Locks. Variety of storage option includes, top mount shelves, wall mountable cabinets, wall tables with under-bench shelves & drawers, movable cabinets etc.